Install
Download the installer and run it. It installs SerialLoom and the Microsoft-signed virtual USB controller that virtual ports use. Because the installer is not code-signed yet, SmartScreen may ask you to confirm: choose More info > Run anyway. Requirements: Windows 10 version 1803 or later, or Windows 11, x64. The installer also sets up SerialLoom Helper, so creating, renumbering and removing virtual ports does not ask for administrator permission each time.
The topology view
SerialLoom opens on the Topology view. The left column lists every COM port Windows knows about: built-in ports, USB adapters, Bluetooth serial links and SerialLoom's virtual ports, with what is using each one. The canvas shows your connections as a graph: ports on the outside, and in the middle the hubs that connect them (split, join, bridge or bus). Every link shows live throughput.
Drag a port onto the canvas to start a split, or onto an existing hub to add it. The toolbar has Split, Join, Bridge, Bus and Virtual pair, and Auto-layout tidies the canvas.
Create a virtual port
Open Virtual ports in the sidebar and press New port. Pick a number such as COM20, or let Windows choose. The port appears in Device Manager as “USB Serial Device (COM20)”; SerialLoom Helper creates it without an administrator prompt. You can also create virtual ports directly while setting up a hub: choose “New virtual port” as an endpoint. More about virtual COM ports.
Virtual null-modem pair
Press Virtual pair. SerialLoom creates two virtual ports wired together. Open one in each program; what one writes, the other reads. More about null-modem pairs.
Split a port
Drag a real port, for example COM3, onto the canvas, keep the “New virtual port” outputs (add as many as you need) and press Create split. Point each program at one of the new ports. Data from the device reaches every program; data from any program goes to the device. The real port is marked M (master) and runs at the baud rate you set for it. More about splitting.
Join ports
A Join merges several ports into one virtual port, for a program that should receive data from several devices. Choose Join, add the ports to merge, and open the joined virtual port in your program.
Bridge to COM or TCP
A Bridge wires two endpoints: COM ↔ COM, COM ↔ TCP server, or COM ↔ TCP client. To share a device on the network, choose your serial port as side A and TCP server 0.0.0.0:7000 as side B. TCP endpoints have no authentication, so use them on trusted networks only. More about serial to TCP.
Bus
On a Bus, every endpoint hears every other endpoint, like devices on an RS-485 multidrop line. Use it to connect three or more programs, or to simulate a fieldbus with several device simulators on one PC.
Traffic monitor
Click a hub to open the inspector. It lists each endpoint with bytes sent and received, current throughput and dropped data, and shows the traffic monitor below: each chunk of data with its time and source port, in ASCII or hex. Pause the stream to read it, or clear it. From the inspector you can also stop and start the hub, add or remove endpoints, and choose whether it starts when SerialLoom opens.
Baud rates
Programs can open a virtual port at any speed from 300 baud to 12 Mbaud, standard or custom, with any data bits, parity and stop bits. The topology shows the setting each program chose (for example 9600 8N1), which helps spot mismatches. Virtual ports always move data at full speed. Real ports use the speed you configure for them in SerialLoom.
Running in the background
Closing the window keeps SerialLoom running in the notification area, so ports and connections stay open. Click the tray icon to bring the window back. Quit SerialLoom in the icon's menu closes every port. Virtual ports exist while SerialLoom runs and come back with the same numbers the next time it starts; hubs set to start automatically resume too. To have ports ready after every restart, turn on Settings > Running in the background > Start SerialLoom in the background when I sign in to Windows.
Renumber and remove ports
Under Virtual ports, Change number gives a port a new COM number; connections using the port follow it. Deleting a port removes it from Windows completely and frees its number. SerialLoom Helper does both without an administrator prompt; without the helper, Windows asks each time. Uninstalling SerialLoom removes all of its virtual ports.
Administrator permission
Creating, renumbering and removing virtual ports changes Windows device settings, which needs administrator rights. SerialLoom Helper, a small Windows service the installer sets up, makes these changes for SerialLoom so Windows does not ask every time. It starts only when needed and stops itself after 10 idle minutes.
The helper can only create, renumber and remove SerialLoom's own ports. It cannot install drivers, change other devices or take a COM number that belongs to real hardware. Settings > Administrator permission shows whether it is installed and can remove it; Windows then asks for each change instead. On a shared PC, note that with the helper installed any signed-in user can create and remove SerialLoom ports through SerialLoom. How the helper is protected.
Automation and command line
Test scripts, build pipelines and your own tools can control SerialLoom: create a virtual null-modem pair before a test and delete it afterwards, connect a real device to a virtual port, or start and stop connections. Every change shows up in the SerialLoom window right away.
- Turn on Settings > Automation > Allow other programs to control SerialLoom. It is off by default, and only programs running under your own Windows account can connect.
- Run
serialloom-cli, installed next to SerialLoom (usuallyC:\Program Files\SerialLoom\serialloom-cli.exe), from a normal terminal, not an administrator one. If SerialLoom is not running, the CLI starts it in the background.
serialloom-cli status Check that SerialLoom can be reached
serialloom-cli pair [COMa] [COMb] Create a virtual null-modem pair, print its ports
serialloom-cli list List connections
serialloom-cli start|stop <connection> Start or stop a connection
serialloom-cli delete <connection> Delete it and the virtual ports it created
serialloom-cli create-port <COMn|COM#>... Create unconnected virtual ports
serialloom-cli renumber <COMold> <COMnew> Give a virtual port another number
serialloom-cli send <json> Send any API request, e.g. a bridge to a real device
A test run with its own pair, in PowerShell:
$cli = "C:\Program Files\SerialLoom\serialloom-cli.exe"
$a, $b = (& $cli pair) -split ' ' # e.g. COM21 COM22
try {
pytest tests/serial --port-a $a --port-b $b
} finally {
& $cli delete $a
}
<connection> is a connection's name or one of its COM ports, and COM# means “the next free number”. Exit codes: 0 success, 1 the command failed, 2 bad usage, 3 SerialLoom not reachable. Add --json for output that scripts can parse.
pair always creates two new virtual ports. To give a program access to a real device, for example a USB adapter on COM6, create a bridge or a split with serialloom-cli send. On test benches and CI machines, run the test runner as the signed-in user that runs SerialLoom, not as a service account.
The automation reference has the full command list, ready-made batch, PowerShell and Python examples, connecting real hardware, test bench setup, and the JSON protocol for using the API directly from any language.
Troubleshooting
My program does not list the virtual port
Make sure SerialLoom is running (check the notification area). In Device Manager, the port should appear under Ports (COM & LPT) as “USB Serial Device (COMn)”, and the controller as “USBip 3.X Emulated Host Controller” under USB controllers. Some programs only scan ports when they start, so restart them after creating a port. Diagnostics on the Virtual ports page shows what SerialLoom sees.
The COM number I want is taken
SerialLoom never takes a number that belongs to real hardware, even when that device is unplugged and only its reservation remains. Pick another number, or remove the old device in Device Manager (View > Show hidden devices) first.
“Access is denied” when opening a port
Another program already has the port open. Use a split to share it.
Remote PCs cannot connect to a TCP server
Check that the server listens on 0.0.0.0 (not 127.0.0.1) and that Windows Firewall allows SerialLoom on that network.
serialloom-cli says SerialLoom cannot be reached
Exit code 3 usually means Settings > Automation is off, or the command ran in an administrator terminal while SerialLoom was not running (the CLI never starts SerialLoom with administrator rights). The CLI also only reaches SerialLoom running under the same Windows account. Run serialloom-cli status from a normal terminal to check.
Still stuck?